S -M Series oleum immersus Power Transformer

Description:

In S -M series olei tres phase transformantis producta societatem adoptat plenam olei conrugatis olei congeriem et signatam piscinam.Oleum testae piscinae aptat ad expansionem olei perficiendam cum sua elasticitate et caloris dissipationis requisitis occurrit.


Product Detail

Product Tags

Product introduction

In S -M series olei tres phase transformantis producta societatem adoptat plenam olei conrugatis olei congeriem et signatam piscinam.Oleum testae piscinae aptat ad expansionem olei perficiendam cum sua elasticitate et caloris dissipationis requisitis occurrit.
Corpus novum velit structuram, ut breve spatium resistat emendare;the core is made of high-quality cold-rolled pii chalybe sheet;the high-voltage and low-voltage windings are made of oxygen free aene wires and adopt multi- layer cylindrical structure;omnes fasteners specialem anti-solventem curatio capere.
Productum proprietates altae efficientiae et humilitatis detrimentum habet, multum potest salvare consumptionem virtutis et gratuita operans et significantes utilitates sociales habet.Plurimum in plantis, substations, industrialibus et fodiendis inceptis, portubus, aeroportibus et aliis locis adhibitum est.

Model Meaning

TYPE TRANSFORMER

Signa

GB/T 1094.1-2013 Potestas Transformatorum - Pars 1: General
GB/T 1094.2-2013 Potentia Transformatores - Pars 2: Temperature oritur pro Transformatoribus liquido-immersis
GB/T 1094.3-2017 Virtutis Transformatores - Pars 3: Insulationis campi, dielectricae probationes et alvi externae in aere
GB/T 1094.5-2008 Virtus Transformatores - Pars V: Facultas brevis circuitionis resistendi
GB/T 1094.10-2003 Potentia Transformatores - Pars 10: Determinatio graduum soni
IEC60076-1:2011 Virtutis transformatores - Pars 1: General
IEC60076-2:2011 Transformatores potentiae - Pars II: Temperatura oritur pro transformatoribus liquido-immersis
IEC 60076-3:2013+AMD1:2018 Transformatores potentiae - Pars III: Insulation gradus, dielectricae probationes et Clearances externae in aere
IEC 60076-5:2006 Power Transformers - Pars V: Facultas brevis circuitionis resistendi
IEC 60076-10:2016 Transformatores potentiae - Pars X: Determinatio gradus soni

Normalis environment conditionibus

1.Ambient Temperature: Non plus quam +40℃
Non minus quam -25℃
Menstrua mediocris temperatus non plus quam + 30℃
Annus mediocris temperatus non plus quam +20℃
2.Altitude: Non plus quam 1000m.
3. Vis aquae intentione copia est similis sine fluctu.
4. Trium phase copiarum vis intentionum proxime symmetriarum est.
5. Totum harmonicum oneris currentis non excedunt 5% of aestimationis;
6.Installation Site: Umbraticis vel velit.

Product characteres

1. Core ferreum e siliconibus scheda ferreis facta est magna qualitate, alta observantia et conductivity magnetico magno, nullo onere depresso.
detrimentum.
2. Alta intentione ambages stratum structuram adoptat.Minimum voltage flexi 500KVA et infra est genus tabulatum, 630kVA et supra producta
spiralem novam capere genus.Princeps vires mechanicae, libratum arripere turn distributionem, fortes ambitum brevem resistentia.
3. Positio structura corpori additur ad vitandam obsessionem per translationem.Eodem tempore omnes fasteners
ligaturae nucibus ornatae sunt, ut claviarii in operatione diuturno non solvantur.
4. Hoc productum est structuram plene signatam.Vacuum oleum de processu impletionis adoptatur cum transformator fasciculus est, qui
humorem transformantis omnino removet, solitudo efficit transfigurantis oleum ab aere extrinseco, prohibet.
senescit oleum, et melioris operationis constantiam transformator.Productum pressionis levamen valvae instructum est;
significat thermometrum, gas Nullam et sic porro ut operationem transformatoris tutandam curaret.
5. Corrugata piscina adoptatur.Hoc genus piscinae commoda habet processus simplicis, vires mechanicae altae, bona glutino
Nullam efficitur et ultrices.Et propter nimiam humorem olei, calor dissipationis capacitas producti melioratur.
6. Productum pulchrum est specie, parvum in volumine et parvum in area area.Liberum productum est specimen sustentationem.

Transformer Product Selection (29)

S11-M Technical Parameter

caRpaatecdity (kvA) Coniunctio intentionis Cognrnoeucpted label diNssoi-ploaatidon (in) dissLiopaadtion (W) 75 Ncuor-rIoeandt (%) Dies Imvpool Energy (%)

ExteIrniostraslilz4e- (x1Lx1W8 xH) (mm)

690 510 920

Pondus (kg)
Princeps(kvVo)ltage Tarapnpgineg Humilis (vkoVl)

30 50

100 130

630/600 910/870

1.5 1.3

275 340

730

510

960

63

150

1090/1040

1.2

750

550

1000

385

80

180

1310/1250

1.2

790

620

1020

450

100

200

1580/1500

1.1

790

700

1040

520

125

DYyynn101 Yzn11 240

1890/800

1.1

840

800

1070

625

160

280

2310/2200

1.0

4.0

1070

670

1130

695

200

66.3 61.06 1101.5

340

2730/2600

1.0

1140

750

1140

795

250

400

3200/3050

0.9

1200

800

1190

955

315

±±2x52.5

0.4

480

3830/3650

0.9

1300

860

1210

1085

400

570

4520/4300

0.8

1380

900

1240

1290

500

680

5410/5100

0.8

1450

950

1300

1590

630

810

6200

0.6

1500

970

1360

1850

800

YYynn101 980

7500

0.6

4.5

1660

1140

1400

2210

1000

1150

10300

0.6

1690

1190

1530

2570

1250

1360

12000

0.5

1760

1230

1600

3115

1600

1640

14500

0.5

1800

1250

1660

3520

2000

1940

18300

0.4

1930

1360

1490

4060

2500

2290

21200

0.4

5

2080

1360

1570

5105

Nota 1 : nam transformatores wlth capacitatem 500kVA et infra aestimabant, pondus damnum valorum supra lineam diagonalem in tabula applicabiles globi copulationis Dyn11 vel Yzn11, et oneris iacturae valores infra lineam diametri applicabiles ad Yyn0 coetus copulationis applicantur .
Nota 2: cum mediocris annui oneris commutatoris est inter 35% et 40%, maximum efficientia operans obtineri potest utendo valore in mensa iactura.

Dimensiones

Transformer Product Selection (89)

S13-M Technical Parameter

caRpaatecdity (kvA) Coniunctio intentionis Cognrnoeucpted label diNssoi-ploaatidon (in) dissLiopaadtion (W) 145 Ncuor-rIoeandt (%) Dies Imvpool Energy (%)

ExteIrniostraslilz4e- (x1Lx1W8 xH) (mm)

695 490 860

Pondus (kg)
  Princeps(kvVo)ltage Tarapnpgineg Humilis (vkoVl)              

30 50

       

80 100

630/600 910/870

1.5 1.3

   

260 365

                 

725

520

955  

63

        110

1090/1040

1.2

 

750

535

970

415

80

        130

1310/1250

1.2

 

770

565

985

465

100

        150

1580/1500

1.2

 

800

595

1000

545

125

      DYyynn101 Yzn11 170

1890/800

1.1

 

815

670

1010

585

160

        200

2310/2200

1.1

4.0

1015

645

1055

695

200

66.3 61.06 1101.5

      240

2730/2600

1.0

 

1020

650

1115

810

250

        290

3200/3050

1.0

 

1140

730

1120

930

315

  ±±2x52.5

0.4

  340

3830/3650

0.9

 

1195

785

1175

1075

400

        410

4520/4300

0.9

 

1265

855

1195

1255

500

        480

5410/5100

0.8

 

1325

915

1240

1435

630

        570

6200

0.8

 

1465

960

1295

1880

800

      YYynn101 700

7500

0.6

4.5

1515

995

1340

2145

1000

        830

10300

0.6

 

1605

1095

1460

2455

1250

        970

12000

0.5

 

1685

1145

1485

2840

1600

        1170

14500

0.5

 

1775

1225

1580

3310

2000

        1550

18300

0.4

 

1855

1265

1600

3960

2500

        1830

21200

0.4

5.0

1885

1305

1780

4980

Nota 1 : nam transformatores wlth capacitatem 500kVA et infra aestimabant, pondus damnum valorum supra lineam diagonalem in tabula applicabiles globi copulationis Dyn11 vel Yzn11, et oneris iacturae valores infra lineam diametri applicabiles ad Yyn0 coetus copulationis applicantur .
Nota 2: cum mediocris annui oneris commutatoris est inter 35% et 40%, maximum efficientia operans obtineri potest utendo valore in mensa iactura.

Transformer Product Selection (89)

S14-M Technical Parameter

caRpaatecdity (kvA) Coniunctio intentionis Cognrnoeucpted label diNssoi-ploaatidon (in) dissLiopaadtion (W) 75 Ncuor-rIoeandt (%) Dies Imvpool Energy (%) ExteIrniostraslilz4e- (x1Lx1W8 xH) (mm) Pondus (kg)
  Princeps(kvVo)ltage Tarapnpgineg Humilis (vkoVl)              

30 50

       

80 100

505/480 730/695

1.5 1.3

  785×710×880 800×730×940

370 480

63

        110

870/830

1.2

  815×720×970

535

80

        130

1050/1000

1.2

  830×740×990

580

100

        150

1260/1200

1.1

  875×790×1010

705

125

      DYyynn101 Yzn11 170

1510/1440

1.1

  875×770× 1050

775

160

        200

1850/1760

1.0

4.0

935×820×1140

975

200

66.3 61.06 1101.5

      240

2180/2080

1.0

  995×870×1140

1140

250

        290

2560/2440

0.9

  995×900× 1180

1240

315

  ±±2x52.5

0.4

  340

3060/2920

0.9

  1030×880×1250

1425

400

        410

3610/3440

0.8

  1075×910×1270

1635

500

        480

4330/4120

0.8

  1120×930×1320

1950

630

        570

4960

0.6

  1165×950×1350

2150

800

      YYynn101 700

6000

0.6

4.5 1210×1050×1390

2515

1000

        830

8240

0.6

  1520× 1020× 1450

2635

1250

        970

9600

0.5

  1630×1090×1540

3210

1600

        1170

11600

0.5

  1680× 1150×1600

3905

2000

        1550

14600

0.4

  1890×1300×1600

4130

2500

        1830

16900

0.4

5.0

1990×1360×1700

5250

Nota 1 : nam transformatores wlth capacitatem 500kVA et infra aestimabant, pondus damnum valorum supra lineam diagonalem in tabula applicabiles globi copulationis Dyn11 vel Yzn11, et oneris iacturae valores infra lineam diametri applicabiles ad Yyn0 coetus copulationis applicantur .
Nota 2: cum mediocris annui oneris commutatoris est inter 35% et 40%, maximum efficientia operans obtineri potest utendo valore in mensa iactura.

Transformer Product Selection (89)

  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis